home | search | email  

home
up
Disp_Group
Acrylamides
Agarose
Blotting
Blotting Membrane
Buffers
Cell Culture Media
Comet Assay Units
Cuvettes
DNA Extraction
Gel Dryer
Gel Doc Systems
Horiz' l Gel Units
Ladders
Luminometers
Mol Biology Kits
Mycoplasma
PCR Cabinet
PCR Plates
PCR Tubes
Protein Clean Up
RNA Extraction
Sample Con'trator
Sequencers
Seq' Products
Spectrophotometer
Stains
Thermal Cyclers
Transilluminators
Vert' Gel Units

Tel: 01543 414704

Fax: 01543 255666

 

Stains

AcrylaGel and Bis-AcrylaGel Image NuclistainTM
 
  • Easy-to-Use
  • Positive Stain
  • High Sensitivity
  • No UV Transilluminator Necessary
Download Protocol
 

National Diagnostics offers an improved method of nucleic acid visualization with the development of Nuclistain. Nuclistain is a positive stain concentrate for the rapid detection of double and single stranded DNA and RNA in agarose and polyacrylamide gels.

Nuclistain is intended as a safer replacement for the conventionally used ethidium bromide. When substituted for ethidium bromide, Nuclistain will detect as little as 50 ng of nucleic acid sample. The advantage of nuclistain is that the results are visible under normal lighting conditions. This eliminates the need for expensive visualization equipment such as UV transilluminators and the time consuming photographic recording of gels. Nuclistain binding is reversible and does not modify nucleic acids.

Nuclistain is extremely easy to use. Simply pour and dilute. One 25 ml bottle of Nuclistain will make 2.5 liters of stain solution. The separated DNA appears as dark blue bands on a light blue background.

Order Number S6-0008

 

Sterling Rapid Silver Stain SterlingTM Rapid Silver Stain
 
  • Detects Sub-Nanogram Levels of DNA or 5 ng of Protein
  • Fix, Wash, and Stain in One Hour
  • Easy System with Fewer Reagents and One Stain
Download Protocol
 

National Diagnostics' STERLING Silver Staining System offers high sensitivity silver staining faster and more conveniently than any other available kit. The unique chemistry of STERLING allows the staining to be carried out in a single solution, whereas standard silver stain procedures require nine or more solutions and washes after fixation. Simply fix a polyacrylamide gel using our unique fixative, wash, and place the gel in the STERLING Staining Solution. Bands will appear in 5-10 minutes. Itıs that simple.

DNA appears as dark brown/black bands on a clear background. Levels as low as 0.1 ng/band can be detected. Proteins, at levels as low as 5 ng/band, appear as black/brown bands. The entire procedure is completed in one (1) hour.

The STERLING Silver Staining System is supplied as a kit, containing 450ml of Stain Reagent A Concentrate, 60 grams of Stain Reagent B (powder) and 100ml of Fixative Concentrate. The kit contains sufficient material to stain 18 mini-gels.

Storage: The components of the STERLING Rapid Silver Stain Kit are stable for 24 months when stored tightly capped in a dark area at room temperature (20oC).

Order Number S6-0010

 

  Triple Dye Loading Buffer (6X)
 
 

With three tracking dyes (Bromophenol Blue, Xylene Cyanol, and Orange G), Triple Dye Loading Buffer (6X) is a nondenaturing loading buffer for native polyacrylamide and agarose gel applications.

Triple dye loading buffer is supplied in 1.2 ml vials containing 50% (w/v) sucrose and 40mM tris base in distilled, deionized water.

Order Number S6-0012

 

ProtoMarkers Image ProtoMarkersTM
 
  • Proteins Stained with High Definition Blue Dye
  • Red Marker Dye Included for Easy Orientation
  • High Contrast, High Intensity Labeling
  • Improved Visibility, Particularly for Western Blots
 
 

National Diagnostics' ProtoMarkers consist of five (5) purified proteins, each permanently labeled with high-contrast blue dye to allow visual tracking of SDS-PAGE and blotting procedures. A non-participatory red dye highlights the 45 kD band, facilitating accurate positioning of the blue bands on the gel. This system combines the clear visualization of high-contrast blue dye with the ease of orientation found with multicolored markers.

ProtoMarkers are pre-mixed in loading buffer, so simply load 5-10 µl per well for mini-gels or 10-20 µl for large format gels. ProtoMarkers Protein Standards range in size from approximately 20 kD to 90 kD, covering the most common protein molecular weights. Because the marker sizes may vary slightly from lot to lot due to inherent variations in the labeling chemistry, the individual sizes are calibrated for each lot and printed on the label for easy reference.

Order Number S6-0028
 

Copyright 2008 - Geneflow Ltd - All Rights Reserved

  home ] Disp_Group ] Acrylamides ] Agarose ] Blotting ] Blotting Membrane ] Buffers ] Cell Culture Media ] Comet Assay Units ] Cuvettes ] DNA Extraction ] Gel Dryer ] Gel Doc Systems ] Horiz' l Gel Units ] Ladders ] Luminometers ] Mol Biology Kits ] Mycoplasma ] PCR Cabinet ] PCR Plates ] PCR Tubes ] Protein Clean Up ] RNA Extraction ] Sample Con'trator ] Sequencers ] Seq' Products ] Spectrophotometer ] [ Stains ] Thermal Cyclers ] Transilluminators ] Vert' Gel Units ]