The
Genova is designed for the scientist whose primary interest is the
study of DNA and proteins. Operation is simple and quick, with all
routinely used DNA calculations being pre-programmed into the product.
The Genova employs a precision built diffraction grating to select
wavelengths and narrow bandwidth, thus avoiding the limited capability
of filter based units. Three independent wavelength calibrations are
performed during the start-up protocol to guarantee optimum confidence
in results and to satisfy G.L.P. procedures.
DNA ANALYSIS
Optimised for low volume analysis the determination of DNA levels as
low as 70ng with sample volumes as low as 20µl is possible using the
capillary sampling accessory. The Genova will automatically calculate
ratios at 260/280 or 260/230 with an optional subtraction of a third
wavelength (typically 320nm). Alternatively, pre-programmed factors
allow direct readings of ssDNA, dsDNA, RNA and Oligonucleotides
PROTEIN ANALYSIS
Genova Life Science Analyser - Protein
-
Standard pre-programmed parameters for B.C.A, Bradford, Biuret,
Lowry and direct measurement
-
Storage of calibration curves
-
Versatile open architecture that allows other wavelengths and
accessories for other assays to be performed
The on-board software allows all protein methodologies to be
optimised and run on the Genova with a minimum of set-up time. These
methodologies can then be viewed on the display for easy
interpretation of linearity of response. The Genova has the
versatility to change these parameters easily for the scientist who
wants to optimise their analyisis with different wavelength, curve
or constant.
DIRECT PHOTOMETRIC MODE
For modes of operation where DNA or protein analysis is not required
the Genova can be used in direct photometric mode. In this mode
concentration, with a choice of units, as well as the absorbance,
transmission and wavelength are displayed.
Specifications
|
Wavelength range |
198-1000nm |
|
Resolution |
1nm |
|
Accuracy |
±2nm |
|
Bandwidth |
5nm |
|
Transmittance range |
0 to 199.9%T |
|
Resolution |
0.1%T |
|
Accuracy |
±1%T@10%T |
|
Stray light |
<0.5%T@340 & 220nm |
|
Absorbance range |
-0.300 to 1.999A |
|
Resolution |
0.001A |
|
Concentration range |
-300 to 1999Conc |
|
Resolution |
0.1 / 1 |
|
Units |
ppm, mg/l, g/l, M, %, µg/l, µg/ml, mg/ml, ng/ml, mM, blank |
ordering
information
| Order Code |
Unit |
Description |
Price |
|
S4-0002 |
Each |
Genova Life Science Spectrophotemeter dedicated for DNA/RNA oligonucleotide & protein analysis supplied with Mains Lead, 8 x 300ul plastic cuvettes, cell holder and instruction manual |
£2,758.00 |
More Spectrophotometers
click here
Also
available; Sipper Pump Micro-Capillaries, Capillary Sample Holder
Copyright 2008 - Geneflow Ltd - All Rights
Reserved |