Semi Dry Blotters

Available in 10 x 10cm, 20 x 20cm, 20 x 50cm and 33 x 45cm sizes.

These Semi Dry Blotters offer rapid transfer times for DNA, RNA and protein blotting - typically 15 to 30 minutes. All units can be used for all types of blotting: western, southern and northern via uncomplicated buffer and set up procedures and are compatible with gel thicknesses from 0.25 up to 10mm without the need for additional equipment. Each unit is compatible with their respective omniPAGE vertical gel system.

Semi Dry Blotting has the added benefit of economic transfers due to very low buffer volumes – typically only a few millilitres of buffer are required per transfer. These Semi-Dry Blotters utilise a screw down lid, which secures the blot sandwich and allows complete control of pressure ensuring even transfer. The electrodes, comprising platinum coated anode and stainless steel cathode, will exhibit practically no corrosion and so provide many years of trouble free use.

Uniform heat dispersion across the blot sandwich ensures stable transfer times and no heat induced sample loss or transfer distortions. Being translucent, it allows viewing of the blot sandwich to ensure correct positioning and transfer is occurring correctly. Electrode plates are fully separated to prevent arching or damage.

  • Rapid transfer times – Transfer can be accomplished in as little as 15 to 30 minutes giving a minimum of delay time from gel running to probing.

  • Suitable for all types of blotting: western, southern and northern – Semi Dry Blotters enable blotting of different types sample via uncomplicated buffer and set up procedures.

  • Wide range of gel thickness can be blotted – Gels from 0.25 up to 10mm thick can be blotted without the need for additional equipment.

  • Economic Transfers due to very low buffer volumes –Typically only a few millilitres of buffer are required per transfer

  •  Screw down lid – Secures blot sandwich and allows complete control of pressure ensuring even transfer.

  • Long life electrodes – Platinum coated Anode and stainless steel cathode ensures practically no corrosion and years of trouble free use

  • Uniform heat dispersion – Across the blot sandwich ensures stable transfer times and no heat induced sample loss or transfer distortions.

  • Ventilation grooves – Further aid homogenous sample transfer.

  • Slot lid arrangement – Positive lid locking retains easy access and ensures any loss of alignment is kept to a minimum.

  • Translucent Lid – Allows viewing of the blot sandwich to ensure correct positioning and transfer is occurring correctly

 

To download pdf please click here ….


 