Semi Dry Blotters
Available in 10 x 10cm,
20 x 20cm, 20 x 50cm and 33 x 45cm sizes.
These Semi Dry Blotters offer rapid transfer times for DNA, RNA and
protein blotting - typically 15 to 30 minutes. All units can be used
for all types of blotting: western, southern and northern via
uncomplicated buffer and set up procedures and are compatible with
gel thicknesses from 0.25 up to 10mm without the need for additional
equipment.
Each unit is compatible with their respective omniPAGE vertical gel
system.
Semi Dry Blotting has the added benefit of economic transfers due to
very low buffer volumes typically only a few
millilitres
of buffer are required per transfer. These Semi-Dry Blotters utilise
a screw down lid, which secures the blot sandwich and allows
complete control of pressure ensuring even transfer. The electrodes,
comprising platinum coated anode and stainless steel cathode, will
exhibit practically no corrosion and so provide many years of
trouble free use.
Uniform heat dispersion across the blot sandwich ensures stable
transfer times and no heat induced sample loss or transfer
distortions. Being translucent, it allows viewing of the blot
sandwich to ensure correct positioning and transfer is occurring
correctly. Electrode plates are fully separated to prevent arching
or damage.
-
Rapid transfer times
Transfer can be accomplished in as little as 15 to 30
minutes giving a minimum of delay time from gel running
to probing.
-
Suitable for all types of blotting: western, southern
and northern
Semi Dry Blotters enable blotting of different types
sample via uncomplicated buffer and set up procedures.
-
Wide range of gel thickness can be blotted
Gels from 0.25 up to 10mm thick can be blotted without
the need for additional equipment.
-
Economic Transfers due to very low buffer volumes
Typically only a few millilitres of buffer are required
per transfer
-
Screw
down lid
Secures blot sandwich and allows complete control of
pressure ensuring even transfer.
-
Long life electrodes
Platinum coated Anode and stainless steel cathode
ensures practically no corrosion and years of trouble
free use
-
Uniform heat dispersion
Across the blot sandwich ensures stable transfer times
and no heat induced sample loss or transfer distortions.
-
Ventilation grooves
Further aid homogenous sample transfer.
-
Slot lid arrangement
Positive lid locking retains easy access and ensures
any loss of alignment is kept to a minimum.
-
Translucent Lid
Allows viewing of the blot sandwich to ensure correct
positioning and transfer is occurring correctly
To download pdf please
click here
.
|